Short answer: On gradients, tonnage alone is not a sufficient selection criterion. Above 15 degrees, derate allowable load by 10-20% and separately check frame torsion and roller rating with one track carrying 70% of total load. Machines with a high centre of gravity or a slewing upper structure also need a lateral overturning moment check. For an 8-ton machine working an 18 degree slope, a 1.25 dynamic factor and 0.85 derating point to a 12-ton class chassis, not a 10-ton one.

1. Why nominal tonnage breaks down on a slope
Catalogue ratings are normally established on level hard ground, static and evenly distributed. On a slope the same machine resolves part of its weight into a downslope force, shifts its centre of gravity away from the contact centre, and adds holding force to the brake and parking system. Those three effects together mean a nominal 10-ton chassis is not a usable 10 tons on a gradient.
Slope projects should therefore start from three inputs - maximum working gradient, centre of gravity height, and whether the upper structure slews - and only then choose tonnage class and track gauge.
2. Derating and dynamic factors
A practical convention: no derating up to 10 degrees, about 5% from 10 to 15 degrees, 10-20% from 15 to 20 degrees, and a dedicated stability calculation plus parking brake above 20 degrees. Apply the dynamic factor on top of that - 1.2-1.3 for general earthmoving, 1.5 for abrasive aggregate and mining.
Worked example: 8-ton machine, 18 degree slope, general earthmoving. Effective allowable load is 8 x 0.85 = 6.8 t; the selection must satisfy 8 x 1.25 / 0.85 = about 11.8 t, so the 12-ton class is the right choice. The arithmetic is approximate, but it avoids the common mistake of sizing exactly to machine weight.

3. Single-track eccentric load and track gauge
Check the eccentric case with one track carrying 70% of total load, focusing on roller bearing ratings and frame torsional stiffness. If the upper structure slews - drilling rigs, cranes, crushing plants - calculate the maximum lateral overturning moment at full slew separately; a longitudinal gradeability calculation does not cover it.
Track gauge is the most direct lever on lateral stability, but widening it raises transport width and turning radius. For export or confined-site projects, consider a telescopic cross beam so the operating and shipping configurations are handled independently.
4. Brakes, track type and acceptance
Slope projects must state the parking brake arrangement - motor-integrated brake or mechanical park - and the fail-safe behaviour on hydraulic pressure loss. On abrasive gradients steel tracks resist slipping better than rubber; rubber remains quieter and kinder on paved surfaces.
Acceptance should include no creep when parked on a 20 degree gradient, a measured full-load gradeability test, and roller temperature rise under eccentric load, with the supplier stating test conditions. A certificate alone rarely tells you under what conditions the numbers were obtained.
5. Gradient and Sizing Reference
| Max gradient | Load derating | Gauge recommendation | Key configuration |
|---|---|---|---|
| Up to 10 degrees | None | Standard gauge | Dynamic factor 1.2 |
| 10 - 15 degrees | About 5% | Standard or one step wider | Verify brake holding |
| 15 - 20 degrees | 10% - 20% | One step wider | 70% single-track check |
| Over 20 degrees | Dedicated calculation | Telescopic beam preferred | Parking brake + overturning check |
Key takeaways
- Slope sizing needs maximum gradient, centre of gravity height and whether the upper structure slews.
- Derate allowable load 10-20% at 15-20 degrees and apply a 1.2-1.5 dynamic factor separately.
- Check 70% single-track eccentric load, plus lateral overturning moment on slewing machines.
- Accept 20 degree parking, full-load gradeability and eccentric-load temperature rise as test evidence.
Further reading
Selection Guide · Products · Case Studies · Applications