Short answer: MAGEON has completed commissioning of a full-load and gradient test rig and folded it into the release inspection of every custom undercarriage. The rig covers 0.5-120 ton static load holding, parking on a simulated 20 degree gradient, single-track eccentric loading and four-hour running temperature rise. Load test reports are shipped alongside material traceability and weld inspection reports, and buyers can specify which raw data items must be retained at order stage.

1. What the new capability adds
Release inspection previously covered dimensional recheck, weld NDT and no-load running, with load verification largely deferred to the customer's first assembly. The new rig adds three checks: a 1.25x rated static load hold, simulated 20 degree gradient parking with no creep, and continuous-running temperature rise on rollers and final drives.
Adjustable ballast and hydraulic loading cover the full 0.5-120 ton range for both steel and rubber track configurations. Non-standard structures such as split frames and telescopic cross beams can be loaded at specific points for local recheck.
2. How the release flow changed
Load testing now sits immediately before packing as the final gate: dimensional and interface recheck, VT/MT weld inspection, then static load, gradient and temperature rise on the rig. A report is issued and the unit released only when all three pass. Any failure returns to assembly, and the test record stays with the work order.
The practical benefit is moving problems that used to surface at the customer's site into the factory. For export projects this matters most - overseas rework logistics and downtime typically cost more than ten times an in-house correction.

3. What data the customer receives
The standard report lists rated load, hold time, gradient angle, parking displacement, continuous-running temperature curve and roller rotation check. Buyers who need the data for their own supplier audit can request strain gauge readings, eccentric load records or third-party witnessed testing at order stage.
Reports are archived by chassis serial number and linked to material heat numbers, consumable batches and WPS/PQR identifiers. If a field issue appears later, the original test data can be retrieved against that serial number.
4. Effect on lead time and specification
The extra rig step leaves catalogue model lead time unchanged and adds roughly one to two days to bespoke builds in the commissioning and load test window. In our view that is a fair trade for OEM supply programmes where the delivered state is verifiable.
We also suggest buyers define the acceptance basis at quotation stage: dimensional conformance only, or load spectrum plus test report. The two differ visibly in inspection cost and lead time, and clarifying early avoids a dispute at delivery.
5. Rig Tests and Acceptance Criteria
| Test | Condition | Criterion | Record |
|---|---|---|---|
| Static load hold | 1.25x rated load | No permanent set, no leakage | Report + photos |
| Gradient parking | Simulated 20 degrees | No creep, brake holds | Displacement log |
| Single-track eccentric | One side takes 70% | No abnormal frame strain | Strain data (optional) |
| Continuous temperature | 4 h running | Rollers below 55C | Temperature curve |
Key takeaways
- Full-load and gradient testing is now part of factory release for custom chassis from 0.5 to 120 tons.
- Three new gates: 1.25x static hold, 20 degree gradient parking and a four-hour temperature rise check.
- Load reports are archived by serial number and linked to heat numbers, consumable batches and WPS.
- Bespoke lead time grows by roughly one to two days; catalogue models are unchanged.
Further reading
OEM/ODM · Products · Case Studies · Contact Us
Prepared by the MAGEON engineering team from custom project records and factory load-test data. Figures are engineering references; final selection should follow approved drawings and the actual duty spectrum.