Choose by one question: will the two ever need to separate? Machines that ship in parts, transfer between sites, or may get a different upper structure later use bolted connections - located by fitted (reamed) bolts plus a machined spigot, holding repeatable alignment at the 0.1 mm class across removal cycles. Upper structures permanently fixed with maximum rigidity demands - crushers and drilling rigs under full load - may be welded, with welds executed to load-bearing weld standards. Both require mounting-face flatness within 0.5 mm per meter. MAGEON's default is fitted bolts plus a spigot: serviceable, precise, with witness marks for torque rechecks. Welding saves weight and adds rigidity at the cost of reversibility. Tell us whether separation is needed and share the upper-structure weight distribution; MAGEON returns a recommendation with connection-face drawings.